WEKO3
アイテム
{"_buckets": {"deposit": "630143c2-8c3a-4ff9-b9c2-90e81b3a5058"}, "_deposit": {"created_by": 8, "id": "415", "owners": [8], "pid": {"revision_id": 0, "type": "depid", "value": "415"}, "status": "published"}, "_oai": {"id": "oai:ryotokuji-u.repo.nii.ac.jp:00000415", "sets": ["21"]}, "author_link": ["806", "912", "922", "1049"], "control_number": "415", "item_10002_alternative_title_1": {"attribute_name": "その他(別言語等)のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Validity of Isometric Muscle Strength Measurements of the Shoulder External Rotation Using a Hand-held Dynamometer with Belt Stabilization", "subitem_alternative_title_language": "en"}]}, "item_10002_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "13", "bibliographicPageEnd": "207", "bibliographicPageStart": "201", "bibliographic_titles": [{"bibliographic_title": "了德寺大学研究紀要"}, {"bibliographic_title": "The Bulletin of Ryotokuji University", "bibliographic_titleLang": "en"}]}]}, "item_10002_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "「目的」肩関節外旋筋力の定量的測定値を得るために,ベルト固定をしたハンドヘルドダイナモメーター測定方法の妥当性を検討した.「対象」若年健常者25名とした.「方法」ベルト固定をしたハンドヘルドダイナモメーターによる肩関節外旋筋力測定は1名の検者が測定した.ハンドヘルドダイナモメーターによる測定の妥当性は,BIODEX による測定値を外的基準とした基準関連妥当性を検討した.「結果」ピアソンの相関係数は有意な相関が認められた(r =0.89).Bland-Altman 分析では固定誤差が認められた.「結論」ベルト固定をしたハンドヘルドダイナモメーターによる肩関節外旋筋力測定方法は,固定誤差を考慮した上で測定値の比較をすることにより,臨床応用に値する妥当性が得られると考えられた.", "subitem_description_language": "ja", "subitem_description_type": "Abstract"}, {"subitem_description": "[Purpose] To investigate the validity of a measurement method using a hand-held dynamometer (HHD) fixed with a belt. The HHD tested the strength of the shoulder external rotation (SER). [Subject] The participants were 25 young healthy adults. [Methods] The strength of the SER was measured by one tester for consistency. The value of the BIODEX was utilized to establish as an objective standard for this study. [Result] Pearson correlation coefficients showed significant correlations between the measurements and the BIODEX standard. Bland-Altman analysis showed a fixed bias. [Conclusion]By considering the fixed bias, comparing the measured values, we thought that muscle strength measurements of the SER using a HHD fixed with a belt would obtain relevance worthy of clinical application.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_10002_identifier_registration": {"attribute_name": "ID登録", "attribute_value_mlt": [{"subitem_identifier_reg_text": "10.18933/00000365", "subitem_identifier_reg_type": "JaLC"}]}, "item_10002_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "了德寺大学"}]}, "item_10002_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12217741", "subitem_source_identifier_type": "NCID"}]}, "item_10002_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1881-9796", "subitem_source_identifier_type": "PISSN"}]}, "item_10002_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "五味, 雅大", "creatorNameLang": "ja"}, {"creatorName": "ゴミ, マサヒロ", "creatorNameLang": "ja-Kana"}, {"creatorName": "Gomi, Masahiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "806", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平野, 正広", "creatorNameLang": "ja"}, {"creatorName": "ヒラノ, マサヒロ", "creatorNameLang": "ja-Kana"}, {"creatorName": "Hirano, Masahiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "912", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "加藤, 宗規", "creatorNameLang": "ja"}, {"creatorName": "カトウ, ムネノリ", "creatorNameLang": "ja-Kana"}, {"creatorName": "Katoh, Munenori", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "922", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "川口, 沙織", "creatorNameLang": "ja"}, {"creatorName": "カワグチ, サオリ", "creatorNameLang": "ja-Kana"}, {"creatorName": "Kawaguchi, Saori", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1049", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-06-26"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ベルト固定を併用したハンドヘルドダイナモメーターによる肩関節外旋筋力測定における妥当性について.pdf", "filesize": [{"value": "1.1 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 1100000.0, "url": {"label": "ベルト固定を併用したハンドヘルドダイナモメーターによる肩関節外旋筋力測定における妥当性について", "url": "https://ryotokuji-u.repo.nii.ac.jp/record/415/files/ベルト固定を併用したハンドヘルドダイナモメーターによる肩関節外旋筋力測定における妥当性について.pdf"}, "version_id": "7810ef7b-3902-4569-ad51-bb0e2f332a05"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "肩関節外旋筋力", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ハンドヘルドダイナモメーター", "subitem_subject_scheme": "Other"}, {"subitem_subject": "妥当性", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Shoulder External Rotation muscle strength", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Hand-Held Dynamometer", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Validity", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "ベルト固定をしたハンドヘルドダイナモメーターによる 肩関節外旋筋力測定における妥当性について", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "ベルト固定をしたハンドヘルドダイナモメーターによる 肩関節外旋筋力測定における妥当性について", "subitem_title_language": "ja"}, {"subitem_title": "Validity of Isometric Muscle Strength Measurements of the Shoulder External Rotation Using a Hand-held Dynamometer with Belt Stabilization", "subitem_title_language": "en"}]}, "item_type_id": "10002", "owner": "8", "path": ["21"], "permalink_uri": "https://doi.org/10.18933/00000365", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2019-05-28"}, "publish_date": "2019-05-28", "publish_status": "0", "recid": "415", "relation": {}, "relation_version_is_last": true, "title": ["ベルト固定をしたハンドヘルドダイナモメーターによる 肩関節外旋筋力測定における妥当性について"], "weko_shared_id": -1}
ベルト固定をしたハンドヘルドダイナモメーターによる 肩関節外旋筋力測定における妥当性について
https://doi.org/10.18933/00000365
https://doi.org/10.18933/0000036501213178-0fc5-4f58-95c6-4e3889ac16b8
名前 / ファイル | ライセンス | アクション |
---|---|---|
ベルト固定を併用したハンドヘルドダイナモメーターによる肩関節外旋筋力測定における妥当性について (1.1 MB)
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-05-28 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | ベルト固定をしたハンドヘルドダイナモメーターによる 肩関節外旋筋力測定における妥当性について | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Validity of Isometric Muscle Strength Measurements of the Shoulder External Rotation Using a Hand-held Dynamometer with Belt Stabilization | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 肩関節外旋筋力 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ハンドヘルドダイナモメーター | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 妥当性 | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Shoulder External Rotation muscle strength | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Hand-Held Dynamometer | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Validity | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ID登録 | ||||||
ID登録 | 10.18933/00000365 | |||||
ID登録タイプ | JaLC | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | Validity of Isometric Muscle Strength Measurements of the Shoulder External Rotation Using a Hand-held Dynamometer with Belt Stabilization | |||||
言語 | en | |||||
著者 |
五味, 雅大
× 五味, 雅大× 平野, 正広× 加藤, 宗規× 川口, 沙織 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 「目的」肩関節外旋筋力の定量的測定値を得るために,ベルト固定をしたハンドヘルドダイナモメーター測定方法の妥当性を検討した.「対象」若年健常者25名とした.「方法」ベルト固定をしたハンドヘルドダイナモメーターによる肩関節外旋筋力測定は1名の検者が測定した.ハンドヘルドダイナモメーターによる測定の妥当性は,BIODEX による測定値を外的基準とした基準関連妥当性を検討した.「結果」ピアソンの相関係数は有意な相関が認められた(r =0.89).Bland-Altman 分析では固定誤差が認められた.「結論」ベルト固定をしたハンドヘルドダイナモメーターによる肩関節外旋筋力測定方法は,固定誤差を考慮した上で測定値の比較をすることにより,臨床応用に値する妥当性が得られると考えられた. | |||||
言語 | ja | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | [Purpose] To investigate the validity of a measurement method using a hand-held dynamometer (HHD) fixed with a belt. The HHD tested the strength of the shoulder external rotation (SER). [Subject] The participants were 25 young healthy adults. [Methods] The strength of the SER was measured by one tester for consistency. The value of the BIODEX was utilized to establish as an objective standard for this study. [Result] Pearson correlation coefficients showed significant correlations between the measurements and the BIODEX standard. Bland-Altman analysis showed a fixed bias. [Conclusion]By considering the fixed bias, comparing the measured values, we thought that muscle strength measurements of the SER using a HHD fixed with a belt would obtain relevance worthy of clinical application. | |||||
言語 | en | |||||
書誌情報 |
了德寺大学研究紀要 en : The Bulletin of Ryotokuji University 号 13, p. 201-207, 発行日 2019 |
|||||
出版者 | ||||||
出版者 | 了德寺大学 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 1881-9796 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12217741 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |