{"created":"2023-06-20T15:54:50.104167+00:00","id":415,"links":{},"metadata":{"_buckets":{"deposit":"630143c2-8c3a-4ff9-b9c2-90e81b3a5058"},"_deposit":{"created_by":8,"id":"415","owners":[8],"pid":{"revision_id":0,"type":"depid","value":"415"},"status":"published"},"_oai":{"id":"oai:ryotokuji-u.repo.nii.ac.jp:00000415","sets":["6:21"]},"author_link":["806","912","922","1049"],"control_number":"415","item_10002_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Validity of Isometric Muscle Strength Measurements of the Shoulder External Rotation Using a Hand-held Dynamometer with Belt Stabilization","subitem_alternative_title_language":"en"}]},"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"13","bibliographicPageEnd":"207","bibliographicPageStart":"201","bibliographic_titles":[{"bibliographic_title":"了德寺大学研究紀要"},{"bibliographic_title":"The Bulletin of Ryotokuji University","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"「目的」肩関節外旋筋力の定量的測定値を得るために,ベルト固定をしたハンドヘルドダイナモメーター測定方法の妥当性を検討した.「対象」若年健常者25名とした.「方法」ベルト固定をしたハンドヘルドダイナモメーターによる肩関節外旋筋力測定は1名の検者が測定した.ハンドヘルドダイナモメーターによる測定の妥当性は,BIODEX による測定値を外的基準とした基準関連妥当性を検討した.「結果」ピアソンの相関係数は有意な相関が認められた(r =0.89).Bland-Altman 分析では固定誤差が認められた.「結論」ベルト固定をしたハンドヘルドダイナモメーターによる肩関節外旋筋力測定方法は,固定誤差を考慮した上で測定値の比較をすることにより,臨床応用に値する妥当性が得られると考えられた.","subitem_description_language":"ja","subitem_description_type":"Abstract"},{"subitem_description":"[Purpose] To investigate the validity of a measurement method using a hand-held dynamometer (HHD) fixed with a belt. The HHD tested the strength of the shoulder external rotation (SER). [Subject] The participants were 25 young healthy adults. [Methods] The strength of the SER was measured by one tester for consistency. The value of the BIODEX was utilized to establish as an objective standard for this study. [Result] Pearson correlation coefficients showed significant correlations between the measurements and the BIODEX standard. Bland-Altman analysis showed a fixed bias. [Conclusion]By considering the fixed bias, comparing the measured values, we thought that muscle strength measurements of the SER using a HHD fixed with a belt would obtain relevance worthy of clinical application.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10002_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.18933/00000365","subitem_identifier_reg_type":"JaLC"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"了德寺大学"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12217741","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1881-9796","subitem_source_identifier_type":"PISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"五味, 雅大","creatorNameLang":"ja"},{"creatorName":"ゴミ, マサヒロ","creatorNameLang":"ja-Kana"},{"creatorName":"Gomi, Masahiro","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"平野, 正広","creatorNameLang":"ja"},{"creatorName":"ヒラノ, マサヒロ","creatorNameLang":"ja-Kana"},{"creatorName":"Hirano, Masahiro","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"加藤, 宗規","creatorNameLang":"ja"},{"creatorName":"カトウ, ムネノリ","creatorNameLang":"ja-Kana"},{"creatorName":"Katoh, Munenori","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"川口, 沙織","creatorNameLang":"ja"},{"creatorName":"カワグチ, サオリ","creatorNameLang":"ja-Kana"},{"creatorName":"Kawaguchi, Saori","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-06-26"}],"displaytype":"detail","filename":"ベルト固定を併用したハンドヘルドダイナモメーターによる肩関節外旋筋力測定における妥当性について.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"ベルト固定を併用したハンドヘルドダイナモメーターによる肩関節外旋筋力測定における妥当性について","url":"https://ryotokuji-u.repo.nii.ac.jp/record/415/files/ベルト固定を併用したハンドヘルドダイナモメーターによる肩関節外旋筋力測定における妥当性について.pdf"},"version_id":"7810ef7b-3902-4569-ad51-bb0e2f332a05"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"肩関節外旋筋力","subitem_subject_scheme":"Other"},{"subitem_subject":"ハンドヘルドダイナモメーター","subitem_subject_scheme":"Other"},{"subitem_subject":"妥当性","subitem_subject_scheme":"Other"},{"subitem_subject":"Shoulder External Rotation muscle strength","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Hand-Held Dynamometer","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Validity","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ベルト固定をしたハンドヘルドダイナモメーターによる 肩関節外旋筋力測定における妥当性について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ベルト固定をしたハンドヘルドダイナモメーターによる 肩関節外旋筋力測定における妥当性について","subitem_title_language":"ja"},{"subitem_title":"Validity of Isometric Muscle Strength Measurements of the Shoulder External Rotation Using a Hand-held Dynamometer with Belt Stabilization","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"8","path":["21"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2019-05-28"},"publish_date":"2019-05-28","publish_status":"0","recid":"415","relation_version_is_last":true,"title":["ベルト固定をしたハンドヘルドダイナモメーターによる 肩関節外旋筋力測定における妥当性について"],"weko_creator_id":"8","weko_shared_id":-1},"updated":"2023-10-12T00:32:38.427706+00:00"}