{"created":"2023-06-20T15:54:46.529030+00:00","id":331,"links":{},"metadata":{"_buckets":{"deposit":"d5383aad-67e4-4436-93cd-aa8c518a7d53"},"_deposit":{"created_by":8,"id":"331","owners":[8],"pid":{"revision_id":0,"type":"depid","value":"331"},"status":"published"},"_oai":{"id":"oai:ryotokuji-u.repo.nii.ac.jp:00000331","sets":["6:17"]},"author_link":["913","387","816","283"],"control_number":"331","item_10002_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Reliability of hip joint abduction muscle strength measurement on supine position using a Hand-held dynamometer","subitem_alternative_title_language":"en"}]},"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"11","bibliographicPageEnd":"176","bibliographicPageStart":"171","bibliographic_titles":[{"bibliographic_title":"了德寺大学研究紀要"},{"bibliographic_title":"The Bulletin of Ryotokuji University","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"本研究の目的は,背臥位でのベルト固定による等尺性股関節外転筋力測定の信頼性を明らかにし,今後の理学療法の発展に繋げていくことである.対象は大学生31名(男性23名,女性8名,平均年齢19.7歳)の右下肢31脚とした.等尺性股関節外転筋力の測定は,Hand-held Dynamometerを使用し,センサー固定用ベルト使用下において背臥位と側臥位の2肢位で行った.測定時間,回数は,約3秒間の最大努力による股関節外転運動を30秒以上の間を空けて3回ずつ行わせ,股関節外転筋力の値は2回目と3回目においての測定値の最大値を採用した.データの分析は,級内相関係数(Intraclass correlation coefficients:ICC),対応のあるt検定,単回帰分析を行った.結果,信頼性に関しては側臥位ICC(1,1)=0.832,背臥位ICC(1,1)=0.974であった.等尺性股関節外転筋力値は背臥位において有意に高値となった.背臥位での計測法は信頼性が高く,多様な場面において計測可能な肢位であることが示唆された.","subitem_description_language":"ja","subitem_description_type":"Abstract"},{"subitem_description":"The purpose of this study is to examine the reliability of the method of hip joint abduction muscle strength measurement by a Hand-held dynamometer(HHD) with a belt.31 healthy subjects were participated in this study.We measured the subjects in the supine position and the lateral position.The interclass correlation coefficient (ICC) was 0.832(lateral position) and 0.974(supine position).The muscular strength was significantly greater in the supine position than in the lateral position.In order to measure hip joint abduction muscle strength,it was suggested that fixing HHD with a belt in supine position is a reliable method.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_10002_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.18933/00000289","subitem_identifier_reg_type":"JaLC"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"了德寺大学"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12217741","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1881-9796","subitem_source_identifier_type":"PISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"清水, 菜穂","creatorNameLang":"ja"},{"creatorName":"シミズ, ナオ","creatorNameLang":"ja-Kana"},{"creatorName":"Shimizu, Nao","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"平野, 正広","creatorNameLang":"ja"},{"creatorName":"ヒラノ, マサヒロ","creatorNameLang":"ja-Kana"},{"creatorName":"Hirano, Masahiro","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"柊, 幸伸","creatorNameLang":"ja"},{"creatorName":"ヒイラギ, ユキノブ","creatorNameLang":"ja-Kana"},{"creatorName":"Hiiragi, Yukinobu","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"加藤, 宗規","creatorNameLang":"ja"},{"creatorName":"カトウ, ムネノリ","creatorNameLang":"ja-Kana"},{"creatorName":"Katoh, Munenori","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-04-04"}],"displaytype":"detail","filename":"2017_01_22.pdf","filesize":[{"value":"1.5 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"Hand-held Dynamometerを使用した背臥位での股関節外転筋力測定方法の信頼性についての検討","url":"https://ryotokuji-u.repo.nii.ac.jp/record/331/files/2017_01_22.pdf"},"version_id":"f03b5c27-ece9-4ab7-ad48-53e931f7d280"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"股関節外転筋力","subitem_subject_scheme":"Other"},{"subitem_subject":"Hand-held Dynamometer","subitem_subject_scheme":"Other"},{"subitem_subject":"信頼性","subitem_subject_scheme":"Other"},{"subitem_subject":"hip joint abductor muscle strength","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Hand-held dynamometer","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"reliability","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Hand-held Dynamometerを使用した背臥位での股関節外転筋力測定方法の信頼性についての検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Hand-held Dynamometerを使用した背臥位での股関節外転筋力測定方法の信頼性についての検討","subitem_title_language":"ja"},{"subitem_title":"Reliability of hip joint abduction muscle strength measurement on supine position using a Hand-held dynamometer","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"8","path":["17"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2017-04-04"},"publish_date":"2017-04-04","publish_status":"0","recid":"331","relation_version_is_last":true,"title":["Hand-held Dynamometerを使用した背臥位での股関節外転筋力測定方法の信頼性についての検討"],"weko_creator_id":"8","weko_shared_id":-1},"updated":"2023-10-10T07:07:17.749794+00:00"}